NA1000FD Gas Detection and Alarm Instrument

NA1000FD Gas Detection and Alarm Instrument

Product Information

Product Model NA1000FD
Product Name Gas Detection and Alarm Instrument
Measurement Range (0~1500) μmol/mol
Allowable Error Limit ±30 μmol/mol or ±5% (display value)
Repeatability ≤3%
Response Time <60s

The NA1000FD Gas Detection and Alarm Instrument is based on the technical principle of a dual-wavelength non-dispersive infrared spectrometer (NDIR) and is equipped with high-performance sensors. It can simultaneously conduct real – time monitoring of sulfur hexafluoride, oxygen, temperature, and humidity in the current environment, display the measurement data in real – time, and transmit the monitoring results to the DCS or the host via RS – 485 or Zigbee signals. Meanwhile, it compares the results with the set alarm values. When the alarm conditions are met, the audible and visual alarm will go off, enabling the staff to promptly detect SF6 leakage and oxygen deficiency and take corresponding measures according to the on – site situation.

Product Features

It uses an OLED display to show the current measured concentration information in real – time.

Users can set the alarm values of the measured gases independently according to the characteristics of the measured gases and on – site requirements.

The measurement data, instrument configuration information, and relay status can be remotely transmitted to the host via RS485 or Zigbee.

After power – on, the instrument automatically checks the configuration information (including sensor installation information) and compares it with the factory – set configuration information to determine if there are any sensor faults.

It can upload the configuration information to the host via the RS – 485 bus and has a fault diagnosis function.

The instrument can be calibrated on – site through key operations or remotely calibrated via the host.

It has obtained the EMC Industrial Level 3 Certification.

Product Parameters

Sulfur Hexafluoride (SF6) Parameters
Parameter Name Parameter Value
Measurement Range (0 – 1500) μmol/mol
Maximum Allowable Error ±30 μmol/mol or ±5% (display value)
Repeatability ≤3%
Response Time < 60 s
Operation Mode Button – type
Oxygen (O₂) Parameters
Parameter Name Parameter Value
Measurement Range (0 – 25)%
Maximum Allowable Error ±0.5% (volume ratio)
Repeatability ≤1%
Response Time < 60 s
Other Parameters
Parameter Name Parameter Value
Temperature – Measurement Range (-40 – 100) °C
Temperature – Maximum Allowable Error ±2 °C ≤1%
Humidity – Measurement Range (0 – 99) %RH
Humidity – Maximum Allowable Error ±5 %RH
Alarm Output – Alarm Relay Contact Capacity – Resistive Load 5 A@250 VAC, 5 A@30 VDC
Alarm Output – Alarm Relay Contact Capacity – Inductive Load 50 VA
Communication – Communication Description RS – 485 (MODBUS), signal output, up to 32 instruments can be connected in parallel
Communication – Connection Shielded twisted – pair cable
Communication – Distance Maximum 1000 m
Input Voltage ±5 24 VDC±15 % (Note: This expression might be incorrect. Please double – check.)
Power 3 W/channel
Insulation Resistance ≥100 MΩ
Insulation Withstand Voltage 1500 V
Dimensions 174 mm * 110 mm * 66 mm (L * W * H)
Weight 0.6 kg